Protocol framework

Knee Osteoarthritis

Focused and radiating ESWT framework for knee osteoarthritis

Moderate evidenceDevice-dependentEducational protocol framework

Protocol framework

Parameter ranges by ESWT modality. Adapt to device, patient and clinical context.

fESWT

Focused ESWT

Level of evidence:GRADE: Moderate
Energy / dose
0.1-0.3mj/mm2
Pulses
2000
Frequency (Hz)
8
Sessions
3
Interval
1/w

rESWT

Radial ESWT

Level of evidence:GRADE: Low
Energy / dose
0.10-0.25bar
Pulses
2000-4000
Frequency (Hz)
6-10
Sessions
3-4
Interval
1/w

ImportantThis is an educational protocol framework. Adapt all parameters to the device, the patient, and your clinical reasoning. Follow manufacturer instructions and local regulations.